INSTRUCTION LEAFLET
Contains vital information on unit operation and installation.
Read and retain carefully. If you are just installing this unit this
leaflet MUST be given to the householder.
*
The Ei105R4 operating range 8 to 16V
Basic informat
READ THIS FIRST
IDEALLY INSTALL IN THE CENTRE OF CEILING AT
LEAST 300mm (12”) FROM LIGHT FITTINGS. KEEP
ION-ISATION ALARMS AWAY FROM KITCHENS TO
PREVENT NUISANCE ALARMS. INTERCONNECT
ALL ALARMS.
ENSURE THE 12V PANEL IS CORRECTLY
CONNECTED TO THE ALARMS.
DO NOT FIT ACTUAL ALARM UNTIL ALL BUILDING
WORK IS COMPLETED TO AVOID CONTAMINATION.
AFTER CHECKING OPERATION, COVER SMOKE
ALARM WITH DUST COVER UNTIL REQUIRED FOR
USE.
LOCATE IONISATION ALARMS (Ei100R3) AWAY
FROM KITCHENS TO PREVENT NUISANCE
ALARMS.
IF A NUISANCE ALARM OCCURS, FAN THE ALARM
VIGOROUSLY WITH A NEWSPAPER TO HELP
CLEAR THE SENSOR.
TEST WEEKLY - PRESS THE BUTTON FOR 10
SECONDS AND A RED LIGHT BEHIND THE BUTTON
OR ON THE COVER SHOULD FLASH.
INTERCONNECTED ALARMS WILL ALSO SOUND.
1
12 VOLT RELAY
SMOKE & HEAT ALARMS
© Ei Electronics 2009
IONISATION
MODEL Ei100R3
OPTICAL
MODELS Ei105R3
Ei105R4
*
HEAT
MODEL Ei103R
P/N B13425 Rev 1
13425-R1-12V COMMON-UC 29/9/09 7:56 AM Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - SMOKE & HEAT ALARMS

INSTRUCTION LEAFLETContains vital information on unit operation and installation.Read and retain carefully. If you are just installing this unit thisl

Seite 2 - LOCATING ALARMS

Other than the cleaning described above, no other customerservicing of this product is required. Repairs, when needed,must be performed by the manufac

Seite 3 - Protection Levels

contamination build-up for example) the alarm can besilenced by disconnecting the 12 Volt supply. Disconnect thealarm with the red light flashing - as

Seite 4

1. Check room doors for heat orsmoke. Do not open a hot door. Usean alternate escape route. Closedoors behind you as you leave.2. If smoke is heavy, c

Seite 5

Heat Alarms on both sides of closed doors and installingmore than one Smoke / Heat Alarm as recommended in thisleaflet very significantly improves th

Seite 6

FIVE YEAR PRODUCT GUARANTEEEi Electronics guarantees this product (excluding battery)against any defects that are due to faulty material orworkmanship

Seite 7 - INSTALLATION INSTRUCTIONS

MODEL (Ei105R4)Supply Voltage: 8.0 to 16.0 VoltsStandby Current: 250 Microamps (max)Alarm Current: 20 to 60 mACable: Multicore low voltage signal cabl

Seite 8

FREQUENT NUISANCE ALARMS OCCUR:(1) Close kitchen / bathroom door when in use.(2) Ensure that the alarm is sited at least 6m away fromsources of fumes.

Seite 9

2READ THIS FIRSTCLEAN YOUR SMOKE ALARM REGULARLY. THISWILL REDUCE THE RISK OF FALSE ALARMS.REMOVE OR COMPLETELY COVER YOUR SMOKEALARM WHEN REDECORATIN

Seite 10

All the Heat Alarms and Smoke Alarms should beinterconnected to ensure the early warning will be heard,particularly by somebody sleeping. A properly d

Seite 11

Single Storey DwellingIf the Home is on one level (a bungalow or mobile home forexample) you should put the first Smoke Alarm in a corridor orhallway

Seite 12

downstairs Smoke Alarm is unlikely to detect the smoke froma fire in a bedroom upstairs (see figure 1).Recommended ProtectionFor recommended protectio

Seite 13 - GETTING YOUR ALARM SERVICED

walls etc). Temperature differences might stop smoke orheat from reaching the unit.• Next to or directly above heaters or air conditioning vents,windo

Seite 14 - SPECIFICATIONS

Wall Mounting (Smoke Alarm only)When a ceiling position is not practical (for example on aceiling having exposed beams or joists, or built-in radianth

Seite 15 - TROUBLESHOOTING

maximum recommended cable resistance is 20 ohms. Allwiring must comply with local codes. Screw unit to ceilingusing screws provided. Put cover back on

Seite 16

After InstallationTest all units by pressing the test buttons in sequence. TheSmoke/Heat Alarm horn should sound within 10 seconds andthe relay contac